Culligan Smart Controller HE DF 12 Installation, Operation, And Service Instructions With Parts Lists page 30

High efficiency 1.5
Table of Contents

Advertisement

Installing the Blocking Solenoid Valve
1.
Mount the solenoid valve securely to the valve using bracket (P/N 01025234).
2.
Remove the conduit nut from the valve.
3.
Insert the wires through the opening.
4.
Secure the valve to the cover using the conduit nut.
5.
Attach the end connector on the solenoid valve wiring to the Aux 4 output connector on the GBE auxiliary board.
6.
Connect the diaphragm valve to the outlet side of the valve using a 1-1/2" coupling (not supplied) and connect
the tubing as shown in Figure 30. We recommend that the pressurized water source is from a soft water supply.
7.
Run the solenoid exhaust line to a suitable drain.
1"X1/2" Reducing Bushing*
1" Coupling*
To Siphon
Break
1/8"NPT x 1/4" Tube Elbow*
Figure 30.
*Not supplied
Culligan® High Efficiency 1.5 Water Filter
26
2
3
1
Blocking Solenoid Valve
(P/N 01016331)
Drain Fitting
Suggested piping and tubing for multi-tank systems.
1/8"NPT x
1/4" Tube Elbow*
1-1/2"
Coupling*
1-1/2" x 3/4"
Reducing
Bushing*
Attach Bracket to Valve
Attach the Blocking Solenoid Valve
to the Bracket
26
1-1/2"
Diaphragm
Valve
(P/N 00445981)
Inlet
1/8"NPT x
1/4" Tube Elbow*
1-1/2" Coupling W/Tap*
1-1/2" Tee*
3/4" Vacuum
Breaker*
Cat. No. 01024514

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents