Installing The Backplane Expander Board - Dell EMC PowerEdge C6400 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge C6400:
Table of Contents

Advertisement

Steps
1. Using the Phillips #2 screwdriver, remove the screws that secure the backplane expander board to the drive cage.
2. Lift the backplane expander board out of the enclosure.
Figure 71. Removing the backplane expander board
Next steps
1.
Install the backplane expander

Installing the backplane expander board

Prerequisites
NOTE:
Observe the routing of the cable on the chassis as you remove them from the system. You must route these
cables properly when you replace them to prevent the cables from being pinched or crimped.
NOTE:
The backplane expander board is only available with 24 x 2.5-inch drives with NVMe configuration.
1. Follow the safety guidelines listed in
Steps
1. Install the backplane expander board into the enclosure, aligning the screw holes on the board with the holes on the drive cage.
2. Using the Phillips #2 screwdriver, secure the backplane expander board to the chassis.
78
Installing and removing enclosure components
board.
Safety
instructions.