Figure 38. Installing a cooling fan
Next steps
1. Follow the procedure listed in
2. Check the management software to see if the fan is rotating at the optimal speed.

Removing the cooling fan cage

Prerequisites
WARNING:
Do not attempt to operate the system without the cooling fans.
WARNING:
The cooling fan spins for some time after the system is powered down. Allow the fan to stop spinning before
removing it from the system.
NOTE:
Observe the routing of the cables when removing them from the system. Route these cables properly when you
replace them to prevent the cables from being pinched or crimped.
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Remove the cooling
fans.
Steps
1. Disconnect the fan power cable from the chassis management board.
2. Lift the cooling fan cage out of the chassis.