NOTE:
•
Install expander firmware 2.07 (X25-00) or later to support these configurations
•
The expander mode works only with a PERC card, and is not supported by the onboard SATA controller.
Diagnostic indicators
The diagnostic indicators on the system indicate operation and error status.
Drive indicator codes
Each drive carrier has an activity LED indicator and a status LED indicator. The indicators provide information about the status of the
drive. The activity LED indicator indicates whether the drive is in use or not. The status LED indicator indicates the power condition of the
drive.
Figure 8. Drive indicators on the drive and the mid drive tray backplane
1. Drive activity LED indicator
2. Drive status LED indicator
3. Drive
NOTE:
If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not turn on.
Table 2. Drive indicator codes
Drive status indicator code
Flashes green twice per second
Off
Flashes green, amber, and then turns off
Flashes amber four times per second
Flashes green slowly
Solid green
Flashes green for three seconds, amber for three seconds,
and then turns off after six seconds
12
Dell EMC PowerEdge C6400 overview
Condition
Identifying drive or preparing for removal.
Drive ready for removal.
NOTE:
The drive status indicator remains off until all drives
are initialized after the system is turned on. Drives are not
ready for removal during this time.
Predicted drive failure.
Drive failed.
Drive rebuilding.
Drive online.
Rebuild stopped.