< Bluetooth >
This is the setting screen activated when "Bluetooth" is
selected on the 4-3-1 INTERFACE SELECT Screen.
4-3-1-1 Authentication Level
Bluetooth
AUTHENTICATION
Level 3
Level 4
NONE
Level 2-1
Level 2-2
NONE:
No authentication
Level 2-1: PIN code authentication, service level, and no
encryption
Level 2-2: PIN code authentication, service level, and
encryption
Level 3:
PIN code authentication, link level, and no
encryption
Level 4:
Supporting secure simple pairing, service level,
and encryption
(Communication with the device that does not
support secure simple pairing.)
Button name and
button pressing
Print/Select
Media feed/Enter
Print/Select +
Media feed/Enter
Print/Select +
Media feed/Enter
+ Press for 3 sec. or
more.
24
Set the authentication level.
Default: Level 3
Screen and printer operation
Select "Level 3," "Level 4," "NONE,"
"Level 2-1," or "Level 2-2."
Changes to the SCAN DETECT
screen.
Changed to the INTERFACE
SELECT screen.
Changes to the I/F SETTINGS
screen (page 23).
4-3-1-2 SCAN DETECT
Set the communication protocol.
Bluetooth
SCAN DETECT
Default: ENABLE
ENABLE DISABLE
Button name and
Screen and printer operation
button pressing
Print/Select
Selects "ENABLE" or "DISABLE."
When "ENABLE" is selected
Media feed/Enter
When "DISABLE" is selected
Print/Select +
Changed to the INTERFACE
Media feed/Enter
SELECT screen (page 23).
Print/Select +
Media feed/Enter
Changes to the I/F SETTINGS
+ Press for 3 sec. or
screen (page 23).
more.
4-3-1-3 PARAMETER SETTING (ISI)
Set the communication parameter ISI.
Bluetooth
Hexadecimal display.
SETTING(ISI)
Displayed when SCAN DETECT is
set to "ENABLE."
0800
Initial value: 0800
Setting range: 0012 to 1000
• The setting value is enabled when the power is supplied
on the next time.
• If a value smaller than ISW is set, an error sound is output
and the value is not set.
• The setting is even only.
The last digit must be 0, 2, 4, 6, 8, A, C, or E.
Button name and
Screen and printer operation
button pressing
Print/Select
Select the digit.
Cursor position...the last digit
Media feed/Enter
Cursor position...other than the
last digit
Cursor position...the most
significant digit
Print/Select +
Media feed/Enter
Cursor position...other than the most
significant digit
Print/Select +
Media feed/Enter
Changes to the I/F SETTINGS
+ Press for 3 sec. or
screen (page 23).
more.
• Changes to the
communication parameter ISI.
• Changes to the
communication parameter
PSI (page 25).
• Changes to the ISW screen
(page 25).
• Moves the cursor
• Changes to the SCAN
DETECT screen.
• Moves the cursor

Hide quick links: