Minimum Startup Configuration - Fujitsu PRIMERGY TX1310 M3 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX1310 M3:
Table of Contents

Advertisement

Appendix
17.4

Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
1 CPU with heat sink
1 CPU fan
1 memory module
1 PSU
Table 7: Minimum startup configuration - components
Cable
Power cable
Table 8: Minimum startup configuration - cables
"Shutting down the server" on page 44
Ê
"Disconnecting the power cord" on page 45
Ê
Ê Take the system down to its minimum startup configuration.
"Connecting the power cord" on page 56
Ê
Ê Connect a display to the server.
"Switching on the server" on page 57
Ê
232
Notes
no TPM or expansion cards installed
installed in CPU1
installed in slot CHA1
installed in PSU1
Notes
Upgrade and Maintenance Manual
TX1310 M3