Hydraulic Tester - With Pressure and Flow Capabilities
You must have o-ring face seal (ORFS) adapter fittings
for this tester to use it on the Groundsmaster 455-D.
1. INLET HOSE: Hose connected from the system
circuit to the inlet side of the hydraulic tester.
2. LOAD VALVE: If required, upon turning the valve to
restrict flow, a simulated working load is created in the
circuit.
3. LOW PRESSURE GAUGE: Low range gauge to
provide accurate reading at low pressure, 0 - 1000 PSI.
This gauge has a protector valve which cuts out
when pressure is about to exceed the normal range
for the gauge. The cutout pressure is adjustable.
Special Tools
Low Pressure
Gauge
Gauge
Protector Va ve
l
Inlet Hose
Figure 8
4. HIGH PRESSURE GAUGE: High range gauge to
accommodate pressure beyond the capacity of the low
pressure gauge, 0 - 10,000 PSI.
5. FLOW METER: This meter measures actual oil flow
in the operation circuit, with a gauge rated at 15 GPM.
6. OUTLET HOSE: Hose from the outlet side of the
hydraulic tester to be connected to the hydraulic system
circuit.