Meter (Gerotor) End Disassembly
1. Clamp unit in vise, meter end up. Clamp lightly on
edges of mounting area. Use protective material on vise
jaws. Housing distortion could result if jaws are over
tightened.
2. Remove 5/16" cap screws.
3. Remove end cap.
4. Remove seal from end cap.
5. Remove meter. Be careful not to drop star.
6. Remove seal from meter.
®
Groundsmaster
455-D
Page 4 - 51
Figure 33
Figure 34
Figure 35
Repairs