18. Clamp housing in vise, as shown. Clamp lightly on
edges of mounting area. Do not over tighten jaws.
NOTE: Check to insure that the spool and sleeve are
flush or slightly below the 14 hole surface of the housing.
IMPORTANT: Clean the upper surface of the hous ­
ing by wiping with the palm of clean hand. Clean
each of the flat surfaces of the meter section parts
in a similar way when ready for reassembly. Do not
use cloth or paper to clean surfaces.
19. Install 3" diameter seal in housing.
20. Install spacer plate. Align bolt holes in spacer plate
with tapped holes in housing.
Repairs
Page 4 - 58
Figure 51
Figure 52
®