1.9 ACCESS TO ELECTRICAL INTERFACE
The access to the terminal block to connect the electrical interface connections is by
removing the cover on the left side panel. See the electrical installation section for the wiring
installation. The .875" diameter knock-out holes are made for ½" electrical box connector
fittings.
2.0 EQUIPMENT INSTALLATIONS
GRIDDLE LIMITATIONS (ELECTRICAL APPLIANCES ONLY)
Summary. Electric griddles up to 36" wide, up to 5.5 kW per linear foot of input power, and
with temperature control up to 450°F (230°C) are acceptable to be used under Wells WVU
and GK model hoods. These must be installed according to the requirements illustrated in
figure 1.
Star-max 515, 524, and 536 models, Ultra-max 724 and 736 models, Toastmaster models
TMGE24 and TMGE36, and Wells models G13, G19, and G23 are all acceptable for use under a
Wells Ventless Hood.
Figure 1. Electric griddle installation parameters (Star-Max 36" griddle
shown under WVU-48SS)
25