Wells GK48 Owner's Manual page 5

Ventless universal hood system for electric cooking appliances
Table of Contents

Advertisement

FEATURES & OPERATING CONTROLS continued
ITEM
DESCRIPTION
NO
VENTILATOR EXHAUST DUCT,
1
TOP
VENTILATOR EXHAUST DUCT,
2
FRONT
3
VENTILATOR FAN
HI-EFFICIENCY/CHARCOAL
4
FILTER PACK
5
NAMEPLATE
6
FIRE SUPPRESSION TANK
7
ACTUATOR ASSY
8
ANSUL® CARTRIDGE
9
MANUAL PULL STATION
10
ADJUSTABLE LEGS
11
AIR WALL
12
DISCHARGE NOZZLES
13
ELECTRICAL DETECTORS
14
APPLIANCE LIGHT
15
GREASE DRIP TRAY
16
BAFFLE FILTER
17
PRE-FILTER ASSEMBLY
18
ELECTRICAL CONNECTION BOX Houses electrical components
19
GROUND LUG
EQUIPMENT INTERFACE
20
CONTACTOR
21
BUILDING FIRE ALARM RELAY
DETECTION END OF LINE
22
RELAY
SUPPLY CONNECTION
23
TERMINAL BLOCK
24
FILTER INTERLOCK SWITCHES
FEATURES & OPERATION CONTROLS
Exit point for ventilator airflow - on top of unit. DO NOT BLOCK
Exit point for ventilator airflow - on front of unit. DO NOT BLOCK
Provides air movement for ventilation
Removes grease and smoke particles. Also assists in cooking
odor removal.
Gives manufacturer, make and model description. Also list
voltage and amperage data.
Container for ANSUL® Low-pH Liquid fire suppression fluid.
Triggers deployment of suppression fluid through manual pull
station or electric detection.
Propels suppression liquid through suppression manifold and
nozzles.
Provides a means of manual activation of the fire suppression
system. PULL ONLY IN CASE OF FIRE!
Allows the unit to be leveled.
A wall of air that moves the grease and smoke particles into the
filter system.
Fire suppression media discharges here, (6 places 48", 12
places 96")
Designed to activate at certain temperature. Activates (i.e. fire
on the cooktop) activates fire suppression system. Should be
checked every 6 months during ANSUL® Service Inspection
ON when hood power switch is ON. Illuminates cooking area.
Collects grease/moisture dripping from baffle filter (16)
Extracts and drains most greases and moisture from the air flow.
Comprises the PRE-FILTER FRAME and a replaceable PRE-
FILTER. Stops large particles of grease from reaching the
FILTER PACK for reduced maintenance costs.
Ground wire of power connection connects here.
Energizes cooking appliances only while ventilator section is
sensed as operational.
Reports fire alarm condition to building fire management system.
Prevents appliance operation if a fault is found in detection
circuit.
Provides connection point for electrical circuitry
Proper installation of baffle filter and filter pack closes these
switches in ventilator sensor circuit
3
COMMENT