Hot plug components
V
CAUTION!
Make sure that the connections on the board are not covered by
fastening clips.
Ê Repeat this procedure with the other fastening clips.
Commissioning the PCI board
– Insert the PCI board, attached to the removal aid, into the PCI slot.
– Close the clip (1) on the slot again (see
the green plastic insert from behind into the housing until it locks into place.
– If there is a cable, attach it to the new PCI board.
– Press the standby button (1, see
The standby indicator and the power indicator light-up orange.
The slot is in the enable sequence.
– Wait until the power indicator and standby indicator light up green.
The slot is now powered on.
I
If the standby LED continues to flash, this indicates that an error has
occurred.
Remove the PCI board and repeat the procedure as described above.
– Close the housing cover again (see
page
100).
RX600 S3 SAS
figure 32 on page
figure 31 on page
"Opening/closing the housing" on
Operating manual
Hot-plug PCI boards
93) by pressing
92).