Safety
Before starting up
V
CAUTION!
During installation and before operating the device, observe the
instructions on environmental conditions for your device (see
"Technical data" on page
If the server has been moved from a cold environment, condensation
may form both inside and on the outside of the machine.
Wait until the server has acclimatized to room temperature and is
absolutely dry before starting it up. Material damage may be caused
to the server if this requirement is not met.
Only transport the server in the original packaging or in packaging
that protects it from impacts and jolts.
Installation and operation
V
CAUTION!
If the unit is integrated into an installation that draws power from an
industrial power supply network with an IEC309 connector, the power
supply's fuse protection must comply with the requirements for non-
industrial power supply networks for type A connectors.
The device automatically adjusts itself to a mains voltage in the range
of 200 V - 240 V. Ensure that the local mains voltage lies within these
limits.
This device must only be connected to a properly grounded shock-
proof socket using tested and approved power cables.
Ensure that the power sockets on the device and the grounded shock-
proof sockets are freely accessible.
The On/Off button or the main power switch (if present) does not
isolate the device from the mains power supply. To disconnect it
completely from the mains power supply, unplug all network power
plugs from the grounded shockproof sockets.