Hot plug components
Replacing the HDD module
If you want to replace a hard disk drive while the server is online, proceed as
follows:
Ê Pull out the HDD module a few centimeters.
V
CAUTION!
Under no circumstances should you remove a HDD module while the
system is in operation if you are not sure that the hard disk drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 5, 10 or 50.
Only remove a HDD module while the server is online if the drive is
not currently being accessed. Observe the control LEDs for the corre-
sponding HDD module (see
page
58).
Ê Wait at least 60 seconds.
I
This waiting period is necessary for the RAID controller to recognize
that an HDD module has been removed and for the hard disk drive to
stop.
Ê Pull out the HDD module fully.
Ê Insert the new HDD module as described under
on page 83
and
V
CAUTION!
If you have removed a HDD module and not replaced it with another one,
you must insert the dummy unit again due to cooling requirements, the
applicable EMC (electromagnetic compatibility) regulations, and for fire
safety. Ensure that the dummy unit engages correctly in the slot.
RX600 S3 SAS
"Installing the HDD module" on page
Operating manual
Hot-plug hard disk drives
"Indicators on the hard disk drives" on
"Unlocking an HDD module"
84.
85