Programming Key Functions - Wells WFAE55F Owner's Manual

Electric open frypot fryer with auto-lift
Hide thumbs Also See for WFAE55F:
Table of Contents

Advertisement

OPERATION - WFAE & WVAE-55FC (SOLID STATE CONTROLS)
CAUTION:
BURN HAZARD
Hot oil can cause serious burns
on contact. Wear appropriate
protective clothing when using
this fryer.
1
FRYER - OFF - FILTER Switch
2
TIME Key
3
TEMP Key
4
DIGTIAL Display
5
HEAT INDICATOR
6
PROGRAM INDICATOR
7
PROGRAM Key
8
ARROW Keys
NOTE:
Solid state controller is shipped
from the factory with all
PROGRAM keys programmed
for ZERO time and 350ºF
(176ºC).
IMPORTANT:
DO NOT USE SOLID
SHORTENING THE FRYER IS
NOT EQUIPPED WITH THE
SOLID SHORTENING MELT
OPTION.
DO NOT USE LARD.

PROGRAMMING KEY FUNCTIONS

OPERATING INSTRUCTIONS
TO PROGRAM TIME
1. PRESS AND HOLD THE TIME PROG KEY 3 SECONDS
DISPLAY WILL READ "Prog"
2. SELECT A KEY 1-4 TO PROGRAM
3. ADJUST TIME UP OR DOWN USING KEYS 1 AND 4
4. PRESS PROG KEY TO ACCEPT
CONTROL IS NOW READY FOR PRE ALARM TIME SET (OPTIONAL)
5. ADJUST PRE ALARM UP OR DOWN USING KEYS 1 AND 4, OR
1
6. PRESS PROG KEY TO ACCEPT (DEFAULT VALUE "0")
7. SELECT ANOTHER KEY TO PROGRAM AND REPEAT STEPS 2-6
8. PRESS TIME PROG KEY TO EXIT PROGRAM MODE
TO PROGRAM TEMPERATURE
1. PRESS AND HOLD THE TEMP PROG KEY 3 SECONDS
DISPLAY WILL READ "Prog"
2. SELECT EITHER KEY 1 OR 4 TO PROGRAM
3. CHOOSE C (CELSIUS) OR F (FAHRENHEIT) USING KEYS 1 OR 4
4. PRESS TEMP PROG KEY TO ACCEPT
FRYER
5. SET TEMPERATURE USING KEYS 1 AND 4 * DO NOT EXCEED 375F/190C
6. PRESS TEMP PROG KEY TO ACCEPT
7. PRESS TEMP PROG KEY AGAIN TO EXIT PROGRAM MODE
OFF
TO START A TIMING CYCLE
PRESS A PRODUCT KEY 1-4
TO RESPOND TO A DONE ALARM
FILTER
PRESS THE ACTIVE PRODUCT KEY 1-4
TO STOP A TIMING CYCLE
PRESS AND HOLD THE ACTIVE PRODUCT KEY 3 SECONDS
TO VIEW ACTUAL TEMPERATURE
PRESS THE TEMP KEY (FIRST DIGIT OF DISPLAY WILL BE "A")
TO VIEW SET TEMPERATURE
PRESS THE TEMP KEY 2 TIMES (FIRST DIGIT OF DISPLAY WILL BE "P")
As each control panel key is pressed, a "beep" will sound. Illuminated
indicator light for each key will light whenever that key is pressed, and
any time the function associated with that key is active.
FRYER - OFF - FILTER switch (item 1) allows the fryer to be placed
in a normal cook mode (FRYER), an oil-filtering mode (FILTER) or
turned OFF.
TIME key controls time functions.
TEMP key controls temperature functions. Data can be read on the
solid state READOUT.
HEAT indicator is lit whenever the burners are energized; READY
indicator is lit when cooking oil is at programmed temperature.
ARROW keys are used to scroll through program settings.
PROGRAM keys allow a choice of 4 pre-programmed time / temp
settings.
Press any PROGRAM key to start a timing cycle and the display
will immediately start to count down.
Any selected PROGRAM key can be cancelled by pressing and
holding for 3 seconds.
CANCEL the Alarm signal by pressing the same PROGRAM key.
PROGRAM INDICATOR illuminates to show which program is
running.
15
DISPLAY DESCRIPTIONS
Lo
FRYER IS BELOW COOKING TEMPERATURE
rEdY
FRYER HAS REACHED COOKING TEMPERATURE
done
COOK CYCLE HAS BEEN COMPLETED
Hi
FRYER HAS EXCEEDED COOKING TEMPERATURE
2
4
PROG
PROG
5
TIME
TEMP
BASKET
HEAT
DOWN
6
3
4
1
2
7
IL2544
3
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wvae55fcWfae55fcWvae55f