INSTALLATION (continued)

ELECTRICAL INSTALLATION

Refer to the nameplate on the front of the fryer and to the specifications
listed on page 1 of this manual. Verify that electric service voltage,
phase and amperage capacity meet or exceed these specifications.
Field wiring must be no less than 4 ga. solid copper wire, rated for at
lease 90ºC.
Fryers are shipped from the factory wired for 3ø. Fryer is not approved
for conversion to single phase.
IMPORTANT:
Field wiring must be routed and secured away from the FRYPOT,
TUBING and FILTER PUMP MOTOR. Field wiring must be configured
to allow access to the rear of fryer for cleaning and access to the filter
pump motor RESET BUTTON.
9
IMPORTANT:
Electric installation of this
appliance must be performed
by a licensed electrician.
Installation must conform
to the requirements of local
codes and ordinances, and
to the requirements of the
National Electrical Code.
FILTER
PUMP &
FRYPOT
MOTOR
POWER
CORD
Fig. 2 Field Wiring
IMPORTANT:
This appliance is rated for
3ø electric service only, and
is not UL approved for single
phase operation.
DO NOT convert this
appliance to single phase.
Doing so will void the
warranty and invalidate the
UL listing.
STRAIN
RELIEF
FITTING
IL2556