Unpacking And Inspection; Electrical Installation - Wells F30 Owner's Manual

30lb countertop electric fryer
Table of Contents

Advertisement

INSTALLATION
NOTE: DO NOT discard
the carton or other packing
materials until you have
inspected the appliance for
hidden damage and tested it
for proper operation.
Refer to SHIPPING DAMAGE
CLAIM PROCEDURE on the
inside front cover of this
manual.
CAUTION:
RISK OF
DAMAGE
DO NOT connect or energize
this appliance until all
installation instructions are
read and followed. Damage
to the appliance will result
if these instructions are not
followed.
WARNING:
Improper installation,
adjustment, alteration, service
or maintenance can cause
property damage, injury or
death. Read the installation,
operating and maintenance
instructions thoroughly before
installing or servicing the
equipment.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective
plastic film, packing materials and accessories from the appliance before
connecting performing any installation procedure.
Carefully read all instructions in this manual and the Installation
Instruction Sheet packed with the appliance before starting any
installation.
Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding
packing materials. Store all accessories in a convenient place for later
use.

ELECTRICAL INSTALLATION

This fryer is equipped for the voltage and wattage indicated on the
nameplate mounted on the bottom of the unit, just left of the power
switch. It is designed for use on alternating current (AC) only. It is
intended for use by properly trained personnel only.
DO NOT CONNECT TO DIRECT CURRENT (DC)
The installation of the appliance should conform to the:
NATIONAL ELECTRIC CODE AND ALL LOCAL ELECTRIC
CODES AND ORDINANCES AND THE LOCAL ELECTRIC
COMPANY RULES AND REGULATIONS
For your protection we recommend that a qualified electrician install
this appliance. He should be familiar with electrical installations and all
electrical codes. Proper connections and power supply are essential
for efficient performance. The external wiring should be in conduit or
an approved type of flexible cable suitable for operation at 194°F (90°C)
and of a proper size to carry the load. The supply circuit should be
properly fused and equipped with a means of disconnection, as required
by local electrical code. THE BODY OF THE APPLIANCE SHOULD
BE GROUNDED - DO NOT GROUND TO A GAS SUPPLY LINE. Four
legs are provided and should be installed for ease of cleaning. DO NOT
INSTALL WITHOUT FEET PROVIDED. Level unit by adjusting the
(4) feet which have an adjustment of 1-3/8" (34.92 mm) for accurate
leveling and perfect line-up with other units.
POWER SUPPLY
These models are wired at the factory for operation on a single phase
power supply. For specific wiring, check the wiring diagram.