A.3

Three-Phase 400 V Class Drives

Maximum Applicable Motor Capacity (HP)
Input
Input Current (A)
Output Current (kVA)
Output Current (A)
Output
Power Supply
Harmonic Countermeasures
Heat Generation (W)
<1> The motor capacity (HP) refers to a NEC 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current.
<2> Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 460 V.
<4> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<5> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
Maximum Applicable Motor Capacity (HP)
Input
Output
Power Supply
Harmonic Countermeasures
Heat Generation (W)
<1> The motor capacity (kW) refers to a Yaskawa 4-pole motor. The rated output current of the drive output amps should be equal to or greater than the motor rated current.
<2> .Input current rating varies depending on the power supply transformer, input reactor, wiring conditions, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 440 V.
<4> Carrier frequency is set to 2 kHz. Current derating is required in order to raise the carrier frequency.
<5> Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
Note: Differences between Heavy Duty ratings and Normal Duty ratings for the drive include rated input and output current, overload capacity, carrier frequency, current limit, and
maximum output frequency. Set parameter C6-01 to "0" for Heavy Duty ratings or "2" for Normal Duty ratings. The default is Normal Duty (C6-01 = 1).
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Table A.4 Power Ratings
Item
CIMR-Vo4A
ND Rating
<1>
HD Rating
ND Rating
<2>
HD Rating
ND Rating
<3>
HD Rating
ND Rating
HD Rating
Overload Tolerance
Carrier Frequency
<3>
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
Rated Voltage Rated Frequency
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
DC Reactor
ND Rating
HD Rating
Table A.5 Power Ratings Continued
Item
CIMR-Vo4A
<1>
Input Current (A)
<2>
Output Current (kVA)
<3>
Output Current (A)
Overload Tolerance
Carrier Frequency
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
Rated Voltage Rated Frequency
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
0001
0002
0.5/0.75/1.
0.25
0
0.25
0.5/0.75
1.2
2.1
1.2
1.8
0.9
1.6
<4>
0.9
1.4
<5>
1.2
2.1
<4>
1.2
1.8
<5>
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
2 kHz (user-adjustable from 2 to 15 kHz)
Three-phase: @380 to 480 V (proportional to input voltage)
19.6
32.4
30.6
43.8
ND Rating
HD Rating
ND Rating
HD Rating
ND Rating
<4>
HD Rating
<5>
ND Rating
<4>
HD Rating
<5>
<3>
DC Reactor
ND Rating
HD Rating
A.3 Three-Phase 400 V Class Drives
Specification
0004
0005
0007
0009
1.5/2.0
3.0
3.0
5.0
1.0/1.5/2.0
3.0
3.0
5.0
4.3
5.9
8.1
9.4
3.2
4.4
6.0
8.2
3.1
4.1
5.3
6.7
2.6
3.7
4.2
5.5
4.1
5.4
6.9
8.8
3.4
4.8
5.5
7.2
400 Hz (user-adjustable)
Three-phase: 380 to 480 V 50/60 Hz
-15 to 10%
±5%
Optional
47.3
66.3
87.0
95.1
60.2
96.9
111.7
117.5
Specification
0018
0023
0031
10.1
14.8
20.1
7.4
10.1
14.8
20.0
24.0
38.0
15.0
20.0
29.0
13.3
17.5
23.6
11.3
13.7
18.3
17.5
23.0
31.0
14.8
18.0
24.0
ND Rating: 120% of rated output current for 60 s
HD Rating: 150% of rated output current for 60 s
(Derating may be required for applications that start and
stop frequently)
2 kHz (user-adjustable from 2 to 15 kHz)
Three-phase: @380 to 480 V (proportional to input
voltage)
400 Hz (user-adjustable)
Three-phase: 380 to 480 V 50/60 Hz
-15 to 10%
±5%
Optional
261.3
321.1
433.6
228.7
285.2
372.8
0011
7.5
5.0
14.0
10.4
8.5
7.0
11.1
9.2
127.7
148.7
0038
24.8
20.1
44.0
39.0
29.0
23.6
38.0
31.0
475.0
445.7
A
285