6.7

Auto-Tuning Fault Detection

Auto-Tuning faults are shown below. When the following faults are detected, the fault is displayed on the Digital Operator and the motor coasts to a stop.
No fault or alarm outputs will occur

Auto-Tuning Codes, Causes, and Possible Solutions

u
LED Operator Display
Er-01
Cause
Motor data or data entered during Auto-Tuning
incorrect.
Motor output and motor-rated current settings (T1-02
and T1-04) do not match.
Motor output and no-load current settings (T1-04 and
E2-03) do not match.This data is required only when
Auto-Tuning for Open Loop Vector Control or when
performing Stationary Auto-Tuning.
Base frequency and base motor rotations (T1-05 and
T1-07) do not match.
LED Operator Display
Er-02
Cause
Motor data entered during Auto-Tuning was incorrect.
The wiring is faulty.
Load is too heavy.
LED Operator Display
Er-03
Cause
Auto-Tuning canceled by pressing STOP button.
LED Operator Display
Er-04
Cause
Motor data entered during Auto-Tuning was incorrect.
Auto-Tuning did not complete within designated time
frame.
Drive-calculated values outside parameter setting range.
LED Operator Display
Er-05
Cause
Motor data entered during Auto-Tuning was incorrect.
Auto-Tuning did not complete within designated time
frame.
Drive-calculated values outside parameter setting range.
LED Operator Display
Er-08
Cause
Motor data entered during Auto-Tuning was incorrect.
Auto-Tuning did not complete within designated time
frame.
Values calculated by the drive are outside the allowable
parameter setting ranges.
LED Operator Display
Er-09
Cause
The motor did not accelerate for the specified
acceleration time.
Torque limit when motoring is too low (L7-01 and
L7-02).
LED Operator Display
Er-11
Cause
Torque reference is too high. (Enabled in OLV only.)
LED Operator Display
Er-12
YASKAWA ELECTRIC SIEP C710606 18A YASKAWA AC Drive – V1000 Technical Manual (Preliminary)
Table 6.11 Auto-Tuning Codes, Causes, and Possible Solutions
Motor Data Error
• Check that the motor data entered to the T1 parameters match the information written on the motor nameplate input before Auto-Tuning.
• Start Auto-Tuning over again and enter the correct information.
• Check the drive and motor capacities.
• Correct the settings of parameters T1-02 and T1-04.
• Check the motor-rated current and no-load current.
• Correct the settings of parameters T1-04 and E2-03.
Set T1-05 and T1-07 to the correct value.
Minor Fault
• Motor data entered to the T1 parameters does not match the information written on the motor nameplate. Enter the correct data.
• Start Auto-Tuning over again and enter the correct information.
• Check the wiring and correct defective connections.
• Check around the machine.
• Check the load.
STOP Button Input
Auto-Tuning did not complete properly and will have to be performed again.
Line-to-Line Resistance Error
• Motor data entered to the T1 parameters does not match the information written on the motor nameplate. Enter the correct data.
• Start Auto-Tuning over again and enter the correct information.
• Check and correct faulty motor wiring.
• Disconnect the motor from machine and perform Rotational Auto-Tuning.
No-Load Current Error
• Motor data entered to the T1 parameters does not match the information written on the motor nameplate. Enter the correct data.
• Restart Auto-Tuning and enter the correct information.
• Check and correct faulty motor wiring.
• Disconnect the motor from machine and perform Rotational Auto-Tuning.
Rated Slip Error
• Motor data entered to the T1 parameters does not match the information written on the motor nameplate. Enter the correct data.
• Restart Auto-Tuning and enter the correct information.
• Check and correct faulty motor wiring.
• Disconnect the motor from machine and perform Auto-Tuning.
Acceleration Error (detected only during Rotational Auto-Tuning)
• Increase the acceleration time (C1-01).
• Check if it is possible to disconnect the machine from the motor.
• Check the settings of parameters L7-01 and L7-02).
• Increase the setting.
Motor Speed Fault (detected only when Auto-Tuning is enabled)
• Increase the acceleration time (C1-01).
• Disconnect the machine from the motor, if possible.
Current Detection Error

6.7 Auto-Tuning Fault Detection

Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
Possible Solutions
Error Name
6
245

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents