7.2 Installing Input Fuses

Installing fuses on the drive input side is recommended to prevent internal short circuit. Select
the suitable fuses below or the branch circuit protection in compliance with local electrician
regulations.
200V class single phase:
220V Model
0.2kW (0.25 HP)
0.4kW (0.5 HP)
0.75kW (1 HP)
1.5kW (2 HP)
2.2kW (3 HP)
200V class three phase
220V Model
0.2kW (0.25 HP)
0.4kW (0.5 HP)
0.75kW (1 HP)
1.5kW (2 HP)
2.2kW (3 HP)
3.7kW (5 HP)
400V class three phase
460V Model
0.4kW (0.5 HP)
0.75kW (1 HP)
1.5kW (2 HP)
2.2kW (3 HP)
3.7kW (5 HP)
Input Current I (A)
3.6
7.4
13.5
24
33
Input Current I (A)
2.2
3.7
6.6
10.5
14.8
21.5
Input Current I (A)
2.7
4.4
6.7
9.3
12.9
154
Line Fuse
I (A)
Bussmann P/N
6
10
20
30
40
Line Fuse
I (A)
Bussmann P/N
5
5
10
15
20
30
Line Fuse
I (A)
Bussmann P/N
10
10
10
15
20
FRS-R-6
FRS-R-10
FRS-R-20
FRS-R-30
FRS-R-40
FRS-R-5
FRS-R-5
FRS-R-10
FRS-R-15
FRS-R-20
FRS-R-30
FRS-R-10
FRS-R-10
FRS-R-10
FRS-R-15
FRS-R-20

Hide quick links: