+V is the input terminal for auxiliary power.

4.3.1 Control Circuit Terminals

4.3.1.1 Input Terminals
Terminal
Terminal Type
Code
S1
S2
S3
Multi-Function
S4
Digital Inputs
S5
S6
SC
+V
A1
Multi-Function
Analog Inputs
PE
AC
4.3.1.2 Output Terminals
Terminal
Terminal Type
Code
R1A
Multi-Function
R1B
Relay Output
R1C
FM
Multi-Function
Analog Output
AC
<1> Do not assign frequent switching functions such as ON/OFF to terminals R, which may
Table 4.3.1.1 Control Circuit Input Terminal
Terminal Name
Digital input terminal 1 (forward/stop)
Digital input terminal 2 (reverse/stop)
Digital input terminal 3 (external fault
1)
Digital input terminal 4 (fault reset)
Digital input terminal 5 (Jog)
Digital input terminal 6 (Baseblock)
Digital input common terminal for NPN/PNP mode switch. Select the mode
correctly when connecting.
Auxiliary power terminal +10V
Analog input terminal 1
(main frequency command)
Ground terminal
Common terminal for analog signals
Table 4.3.1.2 Control Circuit Output Terminals
Terminal Name
Relay 1 normal open
Relay 1 normal closed
Relay 1 common
Programmable analog output
terminal (output frequency)
Analog common terminal
28
Terminal Description
Photocoupler, 24 V, 8 mA.
Use NPN/PNP switch to select
multi-function digital input
type. The default is NPN mode.
Analog input power+10V
Voltage input:
0 to 5V or 0 to 10V
Current input:
0 or 4 to 20mA
The ground terminal for control
signals to avoid interference.
Use shielded cables only.
Terminal Description
Relay output
DC 30 V, 1 A
AC 250 V, 5 A
Voltage Output
0 to 10V

Hide quick links: