4.5.1 Country-specific settings

Parameter settings
Parameter
Lambda calculation
CO
calculation
cor
O
measurement
2
Adjustment data settings
Setting
Recalibration interval
Gases for recalibration
Reaction when recalibration Disable
due
Leak test configuration
Leak test interval
HC residue test
National regul. complied with YES
Change CO
setting
cor
Service interval
14
Germany
Standard EU
ON
ON
OFF
OFF
ON
ON
Germany
Standard EU
365 days
365 days
HC, CO,
HC, CO,
CO
CO
2
2
No setting
Days
Days
1 day
1 day
YES
YES
NO
Disabled
Enabled
183 days
183 days
Denmark
Switz.
ON
ON
ON
OFF
ON
ON
Denmark
Switz.
365 days
365 days
HC, CO,
HC, CO,
CO
CO
2
2
No setting
Disable
NO
Days
NO
1 day
YES
YES
YES
YES
Disabled
Disabled
183 days
183 days
France
Holland Italy
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
France
Holland Italy
365 days
365 days 365 days
HC, CO,
No setting HC, CO,
CO
CO
2
No setting
Message No setting
NO
Days
Days
NO
1 day
1 day
YES
YES
YES
NO
YES
YES
Enabled
Disabled Enabled
183 days
183 days 183 days
2