6.3

Checking V-lambda

6.3.1
Terminal diagram of
V-lambda cable
6.4
Checking the ignition point and
dwell angle
First of all, automatic zero calibration takes
place.
3.
Connect the clip-on trigger sensor to
the BEA.
4.
Clamp the clip-on trigger sensor over
the loop of your P 100.
5.
Connect the B-cable of the BEA to the
B-jack of your P 100.
6.
Connect the V-lambda cable to volta-
ge output V, C, R and rR of your P 100.
7.
Connect a digital multimeter parallel
to this.
8.
Set the voltage to 2.500 V.
9.
Compare the value on your digital
multimeter with the value displayed on
the BEA.
Nominal value: 2.500V + 0.1V
black
schwarz
rot
red
i In order to check the ignition point and
the dwell angle, you will require the TD/
TN/Term1 connection cable, Part
No.: 1 684 460 196 (SZB) and timing
light 1 687 022 767 (SZB).
Press F2 or u to go to the menu
1.
Ignition point/Dwell angle and
open it by pressing F5 >> or E.
2.
In the No. of pulses menu, set the
number of pulses to 1 using the o or u
keys.
Best. -Nr.
Solder side
Lötseite
1
2
2
4
5
3
1
3
4
5
465463Ha