8.3

Messages about boot test functions

No.
Message
1010 Checksum error in flashrom
1011 RAM test error
1012 Error in data bus dt1
1013 Error in data bus dt2
1014 Error in data bus dt3
1015 Error in data bus dt4
1016 Error in data bus p1
1017 Error in data bus p2
1018 Disk error
1019 Battery undervoltage
1020 Error in data bus dt5
1021 Error in data bus dt6
1022 Error in video RAM
1023 HD error
1030 Clock faulty or shows incorrect time
Possible cause
Error in software
Faulty flashrom
Faulty RAM module
Error in control module PCB Re-boot BEA, if error still present:
Disk write-protected
Loose interconnecting cables Check that interconnecting
Error in voltage supply
Faulty disk drive
Battery faulty or discharged Check battery, replace if necessary 10.32
Error in control module PCB Replace control module PCB
Error in control module PCB Re-boot BEA, if error still present:
Faulty video RAM module
Loose interconnecting cables Check that interconnecting
Error in voltage supply
Faulty hard disk
Date and time incorrectly set Set date and time correctly,
Remedy
Re-boot BEA, if error still present:
Re-install system software
Replace control module PCB
Re-boot BEA, if error still present:
Replace control module PCB
Replace control module PCB
Remove write protection
cables secure, check for
continuity
Check voltage supply
Check disk drive
Re-install system software
Perform video RAM test
Replace control module PCB
cables secure, check for
continuity
Check voltage supply
Check hard disk, if error
still present: replace hard disk
if error still present:
replace control module PCB
Section
5.23
10.27
10.27
10.27
12.1 and 12.4
10.2 and 10.3
5.9
10.27
10.27
5.13
10.27
12.1 and 12.4
10.2 and 10.4
5.8 and 10.23
5.12
10.27
55