Sinusoidal interference
The table below shows the electromagnetic compatibility of the TS Adapter IE in relation to
sinusoidal interference.
Table 9- 2
Sinusoidal interference
Sinusoidal interference
HF irradiation (electromagnetic fields) according to
IEC 61000-4-3
RF current coupling on cables and cable shields to
IEC 61000-4-6
Radio interference emission
Emission of electromagnetic fields to EN 61000-6-4.
Additional measures
If you want to operate the TS Adapter IE in an office environment, you must ensure
compliance with EN 61000-6-3.
Take suitable measures for increasing resistance to high external interference levels as
required.
TS Adapter IE
Manual, 11/2010, A5E00977705-03
Test values
10 V/m with 80% amplitude modulation of 1 kHz
in the range from 80 MHz to 1000 MHz and
1.4 GHz to 2 GHz.
1 V/m with 80% amplitude modulation of 1 kHz in
the range from 2 GHz to 2.7 GHz
Test voltage 10 V, with 80% amplitude modulation
of 1 kHz in the 10 MHz to 80 MHz range
Specifications
9.4 Electromagnetic Compatibility
Equivalent to
severity
3
3