Working with the TS Adapter IE

7.8 TS Adapter IE Configuration - Overview

7.8
TS Adapter IE Configuration - Overview
Overview
You can use the configuration interface to:
● Configure the TS Adapter IE parameters.
● Restore the TS Adapter IE default configuration.
● Export adapter parameters.
● Import adapter parameters.
Useful facts about configuration
You can configure the TS Adapter IE parameters by direct connection or over a remote
connection.
For configuration you alternatively need:
● The TeleService application
● A browser
If you make changes in one tab of the configuration interface and open another tab without
saving your changes, the changes will be discarded without warning.
If you enter inadmissible values in a tab, the fields in question are colored red as soon as
you click "Save Settings". The incorrect values are not saved in this case. Correct the
incorrect inputs and click "Save Settings" again. As long as you have not yet saved your
input in a tab by clicking "Save Setting", you can cancel them by clicking "Discard Changes".
The configuration data are written to the nonvolatile memory of the TS Adapter IE.
Note
If you change the current parameters while a remote connection is open, there is a risk that
you may not be able to establish a modem connection again with the changed parameters.
In this case, you can only configure the TS Adapter IE parameters by direct connection.
That means that you must configure the TS Adapter IE using a PG/PC on-site or you must
take the TS Adapter IE to the location of the local PG/PC to configure its parameters there.
52
TS Adapter IE
Manual, 11/2010, A5E00977705-03