● If Night Quiet Mode is to be used, initial settings must be made when
the unit is installed.
Explain Night Quiet Mode, as described below, to the customer, and
confirm whether or not the customer wants to use Night Quiet Mode.
About Night Quiet Mode
The Night Quiet Mode function reduces operating sound of the outdoor
unit at nighttime. This function is useful if the customer is worried about
the effects of the operating sound on the neighbors.
However, if Night Quiet Mode is running, cooling capacity will be saved.
Setting procedure
Remove the SW5 jumper switch.
Once the settings are complete, reset the power.
NOTE
Install the removed jumper switch as described below. This switch
will be needed to later disable this setting.
Jumper switch
● Use the S15 connector to set the unit to only cool or heat.
Setting to only heat (H): short-circuit pins 1 and 3 of the connector <S15>
Setting to only cool (C): short-circuit pins 3 and 5 of the connector <S15>
The following specifications apply to the connector housing and pins.
JST products
Note that forced operation is also possible in COOL/HEAT mode.
Installation Manual
Night Quiet Mode Setting
After removing
COOL/HEAT Mode Lock <S15>
Housing: VHR-5N
Pin:
SVH-21T-1,1
Outdoor Unit
Service PC-board
Night Quiet Mode
setting switch (SW5)
COOL mode (C)
HEAT mode (H)
5<C>3<H>1
2
291