Daikin FTXS15LVJU Installation Manual

Daikin FTXS15LVJU Installation Manual

R410a split series room air conditioner
Hide thumbs Also See for FTXS15LVJU:

Advertisement

MODELS
FTXS15LVJU
FTXS18LVJU
FTXS24LVJU
DAIKIN ROOM AIR CONDITIONER

INSTALLATION MANUAL

R410A Split Series

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTXS15LVJU

  • Page 1: Installation Manual

    DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU...
  • Page 2: Safety Precautions

    Safety Precautions • Read these Safety Precautions carefully to ensure correct installation. • This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the precau- tions below: they are all important for ensuring safety. DANGER ..Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING ..Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury. CAUTION ..Failure to follow any of CAUTION may in some cases result in grave consequences.
  • Page 3: Table Of Contents

    Safety Precautions WARNING • During pump-down, stop the compressor before removing the refrigerant piping. If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormally high pressure which could lead to equipment damage or and personal injury. • During installation, attach the refrigerant piping securely before running the compressor. If the refrigerant pipes are not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing abnormally high pressure which could lead to equipment damage and personal injury. • Be sure to install a ground fault circuit interrupter breaker. Failure to install a ground fault circuit interrupter breaker may result in electrically shocks, or fire personal injury. CAUTION • Do not install the air conditioner where gas leakage would be exposed to open flames. If the gas leaks and builds up around the unit, it may catch fire. • Establish drain piping according to the instructions of this manual. Inadequate piping may cause water damage. • Tighten the flare nut according to the specified torque. A torque wrench should be used. If the flare nut is tightened too much, the flare nut may crack over time and cause refrigerant leakage. • Do not touch the heat exchanger fins. Improper handling may result in injury. • Be very careful about product transportation. Some products use PP bands for packaging. Do not use any PP bands for a means of transportation. It is dangerous. • Electrical work must be performed in accordance with the NEC/CEC by authorized personnel only. Accessories A – M , Indoor unit Mounting plate Remote controller holder Tube Mounting plate fixing screw Fixing screw for remote controller Operation manual 3/16” × 1” (M4 × 25mm) holder 1/8” × 13/16” (M3 × 20mm) Titanium apatite photocatalytic Dry battery AAA. LR03 Installation manual air-purifying filter (alkaline)
  • Page 4: A Mounting Plate

    Indoor Unit Installation Drawings How to attach the indoor unit Hook the claws of the bottom frame A Mounting to the mounting plate. plate If the claws are difficult to hook, remove the front grille. Clip How to remove the indoor unit Bottom frame Push up the marked area (at the lower part of the front grille) to...
  • Page 5 Preparation before Installation Removing and installing front panel • Removal method Hook fingers on the tabs on the left and right of the main body, and open until the panel stops. Slide the front panel sideways to disengage the rotating shaft. Then pull the front panel toward you to remove it. • Installation method Align the tabs of the front panel with the grooves, and push all the way in. Then close slowly. Push the center of the lower surface of the panel firmly to engage the tabs. Push the rotating shaft of the front panel into the groove. Removing and installing front grille mark area Upper hook (3 locations) • Removal method 1) Remove front panel to remove the air filter.
  • Page 6: Refrigerant Piping Work

    How to set the different addresses When 2 indoor units are installed in one room, Jumper the 2 wireless remote controllers can be set for different addresses. 1) Remove the metal plate electrical wiring cover. (Refer to the When connecting to an HA system.) 2) Cut the address jumper (JA) on the printed circuit board. ADDRESS ADDRESS:JA EXIST 3) Cut the address jumper (JA) in the remote EXIST controller. When connecting to an HA system (wired remote controller, central remote controller etc.) 1) Remove the front grille. (6 screws) 2) Remove the electrical wiring box. (1 screw) 3) Remove the metal plate electrical wiring cover. (4 tabs) 4) Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure.
  • Page 7: Refrigerant Piping

    Refrigerant Piping Work Refrigerant piping CAUTION • Use the flare nut fixed to the main unit to prevent it from cracking and deteriorating from age. • To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.) • Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage. Align the centers of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches. [Apply oil] [Tighten] Apply refrigeration oil to Do not apply refrigeration Torque wrench the inner surface of the oil to the outer surface. flare. Flare nut Spanner Piping union Flare nut Do not apply refrigeration oil to the flare nut to avoid tightening...
  • Page 8: Indoor Unit Installation

    Indoor Unit Installation Installing the mounting plate • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the plate is completely level, and mark the boring points on the wall. 2) Secure the mounting plate to the wall with screws. Recommended mounting plate retention spots and dimensions Through-the-wall Recommended mounting plate retention (Bolt size : 3/8 (M10)) hole ϕ3-1/8 (ϕ80) spots (9 spots in all) Place a leveler on raised tab. 4-11/16 (Bolt size : 3/8 (M10)) (119)
  • Page 9: H Indoor Unit Fixing Screw

    Indoor Unit Installation Laying piping, hoses, and wiring 3-1. Right-side, right-back, or right-bottom piping 1) Attach the drain hose to the underside of the refrigerant pipes with an adhesive vinyl tape. 2) Wrap the refrigerant pipes and drain hose together with insulation Right-side piping tape. Right-back piping Remove pipe port cover here for right-side piping. Right-bottom piping Bind refrigerant pipe and drain Remove pipe port cover hose together with here for right-bottom piping.
  • Page 10: J Tube

    3-3. Wall embedded piping • Insert the drain hose to this depth so it won’t be pulled out of the drain Insert the drain pipe. Inner wall hose to this depth so it won’t be pulled out of drain pipe. 1-15/16” (50mm) Drain hose or more Vinyl chloride drain pipe Outer wall (VP-30) Wiring With a multi indoor unit , install as described in the installation manual supplied with the Multi outdoor unit.
  • Page 11: Drain Piping

    Indoor Unit Installation Drain piping The drain hose should be inclined downward. 1) Connect the drain hose, as described right. No trap is permitted. Do not put the end of the hose in water. 2) Remove the air filters and pour some water into the drain pan to check the water flows smoothly. 3) When drain hose requires extension, obtain an extension hose commercially available. Be sure to thermally insulate the indoor section of the extension hose. Extension drain hose Indoor unit drain hose Heat insulation tube (field supply) 4) When connecting a rigid polyvinyl chloride pipe (nominal diameter 1/2 inch (13mm)) directly to...
  • Page 12 Trial Operation and Testing Trial operation and testing 1-1 Measure the supply voltage and make sure that it falls in the specified range. 1-2 Trial operation should be carried out in either cooling or heating mode. • In cooling mode, select the lowest programmable temperature; in heating mode, select the highest programmable temperature. 1) Trial operation may be disabled in either mode depending on the room temperature. Use the remote controller for trial operation as described below. 2) After trial operation is complete, set the temperature to a normal level (78°F to 82°F (26°C to 28°C) in cooling mode, 68°F to 75°F (20°C to 24°C) in heating mode). 3) For protection, the system disables restart operation for 3 minutes after it is turned off. 1-3 Carry out the test operation in accordance with the operation manual to ensure that all functions and parts, such as fin movement, are working properly. • The air conditioner requires a small amount of power in its standby mode. If the system is not to be used for some time after installation, shut off the circuit breaker to eliminate unnecessary power consumption. • If the circuit breaker trips to shut off the power to the air conditioner, the system will restore the original operation mode when the circuit breaker is opened again. Trial operation from remote controller 1) Press “ON/OFF” button to turn on the system. 2) Press “TEMP” button (2 locations) and “MODE” button at the same time. 3) Press “MODE” button twice. (“ T ” will appear on the display to indicate that trial operation mode is selected.) 4) Trial operation terminates in approx. 30 minutes and switches into normal mode. To quit a trial operation, press “ON/ OFF” button. Test items Symptom Test items Check (diagnostic display on RC)
  • Page 13 MEMO ■ English...
  • Page 14 Two-dimensional bar code is a code for manufacturing. 3P297301-2 M11B120 (1111) HT...