The Multi-Split Duct-Free System Ftxs15/18Hvju - Daikin Super Multi NX 3MXS-G Series Engineering Data

Table of Contents

Advertisement

EDUS121131
3.3

The Multi-Split Duct-Free System FTXS15/18HVJU

A
Mounting plate
Mounting plate fixing screws
B
3/16" × 1"L (M4 × 25mm)
C
Air-purifying filter with
photocatalytic deodorizing function
D
Wireless remote controller
• Before choosing the installation site, obtain user approval.
1.
Indoor unit.
The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air intake and exhaust have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote controller range,
8) the unit is at least 3.5 ft (1m) away from any television or radio set (unit may cause interference with the picture or sound).
2.
Wireless remote controller.
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are
properly received by the indoor unit (within 23 ft (7m)).
Installation Manual
Accessories
1
E
Remote controller holder
Fixing screws for remote controller
F
10
holder 1/8" × 13/16"L (M3 × 20mm)
2
Dry batteries AAA. LR03 (alkaline)
G
H
Indoor unit fixing screws
1
3/16" × 1/2"L (M4 × 12mm)
Choosing a Site
1
K
Operation manual
2
Installation manual
L
2
2
Indoor Units
2
1
1
253