Outdoor Unit
● Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed.
● In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts. (Prepare four sets of
M3/8" or M7/16" foundation bolts, nuts and washers each which are available on the market.)
● It is best to screw in the foundation bolts until their length are 3/4" from the foundation surface.
● Install the unit horizontally.
● The unit may be installed directly on a concrete verandah or a solid place if drainage is good.
● If the vibration may possibly be transmitted to the building, use a vibration-proof rubber (field supply).
● Where a wall or other obstacle is in the path of outdoor unit's intake or exhaust airflow, follow the installation guidelines
below.
● For any of the below installation patterns, the wall height on the exhaust side should be 4 ft or less.
Wall facing one side
More than 3-15/16
284
Precautions on Installation
Installation
Outdoor Unit Installation Guidelines
More than 13-3/4
47-3/16
or less
Side view
Walls facing two sides
More than 13-3/4
More
than 3-15/16
More than 1-15/16
Top view
Walls facing three sides
More than 3-15/16
More than 13-3/4
More than 1-15/16
Top view
EDUS121131
More than 1-15/16
Unit: in.