SINUMERIK 801
Start-Up
Fig. 5–10 Setting the markers
The markers can also be used to determine the differences in the horizontal or
vertical direction. To this aim, position the marker on the start point and press
either the Fix H - Mark. or the Fix T- Mark. softkey. The difference between the
start point and the current marker position is now displayed in the status bar.
The softkey labeling changes to "Free H - Mark" or "Free T - Mark".
Pressing the Help key softkey calls explanations with regard to the displayed
values on the screen.
Pressing the Start softkey starts recording. The softkey labeling changes to
Stop. The note "Recording active" is displayed.
When the measuring time is elapsed, the softkey labeling changes to Start.
Pressing the Stop softkey aborts the current measuring. The softkey labeling
changes to Start.
Pressing "Zoom Time +"/"Zoom Time - " enables the scaling changes in the
following steps:
1, 2, 5, 10, 20, 50, 100, 200, 500, 1,000 ms/div.
Pressing "Zoom V +"/"Zoom V -" enables the horizontal scaling changes in the
following steps:
0.01, 0.05, 0.1, 0.5, 1, 5, 10, 50, 100, 500, 1,000, 5,000 unit/ div
Pressing the Auto Scaling key calculates the vertical scaling from the peak
values.
Services, Diagnosis and Data Saving