Setting Up
5-14
Set spindle MDs as listed below:
MD
Designation
31020
ENC_RESOL
32260
RATED_VELO
36200
AX_VELO_
LIMIT[ 0 ... 5 ]
Determine the encoder limit frequency:
Spindle speed 3000 rev/min = 50rev/s;
Encoder limit frequency 50 rev/s×1024 pulses/rev = 51200 pulses/s
Fill in weighted machine data:
MD
Designation
36300
MA_
ENC_
LIMIT
For anolog spindle with gear changes:
MD
Designation
35010
GEAR_STEP_
CHANGE_
ENABLE
35110
GEAR_STEP_
MAX_VELO[ 0,
1 ... 5 ]
35130
GEAR_STEP_
MAX_VELOLIMI
T[ 0,1 ... 5 ]
36200
AX_VELO_
LIMIT[ 0, 1 ... 5 ]
31050
DRIVE_AX_
RATIO_
DENUM[0,1 ...
Unit
Axis
IPR
Spindle
RP
Spindle
M
RP
Spindle
M
Unit
Axis
FREQ_
Hz
Spindle
Unit
Axis
-
Spindle
RPM
Spindle
RPM
Spindle
RPM
Spindle
-
Spindle
Input
Description
value
1024
Encoder
markings
per
revolution
(encoder no.)
3000
Rated motor speed
(setpoint branch)
3300
Threshold value for
velocity monitoring
Input
Description
value
55000
Encoder limit
frequency
Input value
Description
1
Gear change
possible.
Spindle has
several gear
steps
Speed
Maximum
[i]
speed for
gear
change(gear
stage no.):
0 ... 5
Speed
Maximum
[i]
speed of gear
stag(gear
stage no.):
0 ... 5
Speed
Threshold
[i]
value for
velocity
monitoring
(control
parameter set
no.): 0 ... 5
Denominator
Denominator
[i]
load gearbox
(control
parameter
SINUMERIK 801
Start-Up

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents