Table 2-17 Pin assignment for connectors X200~X201
Pin
Signal
1
P24
2
S-CW
3
S-CCW
4
T-CW
5
T-CCW
6
Cooling
7
Lubric
8
S-Brake
9
Chuck
10
M24
* In this list, high signal level refers to the 24VDC, current leakage less than
2mA with a simultaneity factor of 0.5.
Signal type
VI
DO
Table 2–18 Electrical parameters of the digital outputs
Parameter
"1" signal, nominal voltage
Voltage drop
"1" signal, output current
"0" signal, leakage current
Notice
See Section 3.2 "Input/Output Configuration" for definitions of X200 ... X201
output signals.
X200
Pin
Signal type
VI
1
DO
2
DO
3
DO
4
DO
5
DO
6
DO
7
DO
8
DO
9
VI
10
Voltage input
Digital output (24 V signal)
Value
24
max. 28.8
0.5
max. 2
X201
Signal
Signal type
P24
VI
User out1
DO
User out2
DO
User out3
DO
User out4
DO
n.c.
n.c.
n.c.
n.c.
M24
VI
Unit
Note
V
V
A
Simultaneity factor