Purpose
For optimum router performance, verify the condition of the Modular Interface Cards (MICs).
Action
On a regular basis:
Check the LEDs on MIC faceplates. The meaning of the LED states differs for various MICs. For more
information, see the
MX Series Interface Module
MIC failure, the MPC generates an alarm message to be sent to the Routing Engine.
Issue the CLI show chassis fpc pic-status command. The MIC slots in an MPC are numbered PIC 0/1
and PIC 2/3, top to bottom:
user@host> show chassis fpc pic-status
Slot 4
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
4x 10GE(LAN) SFP+
Reference. If the MPC that houses the MIC detects a
MPC4E 3D 2CGE+8XGE