Power Supply Capacities And Power Losses; Input Power Supply, Molded-Case Circuit Breaker, And Fuse - YASKAWA SGDV User Manual

Ac servo drives dc power input design and maintenance
Hide thumbs Also See for SGDV:
Table of Contents

Advertisement

3.1.4 Power Supply Capacities and Power Losses

The following table shows the SERVOPACK's power supply capacities and power losses.
Maximum
Main
Applicable
Circuit
Servomotor
Power
Capacity
Supply
24 VDC
48 VDC

3.1.5 Input Power Supply, Molded-case Circuit Breaker, and Fuse

Use input power supplies that meet the following conditions.
• The main circuit power supply must be a 24-VDC or a 48-VDC power supply.
• The control circuit power supply must be a 24-VDC power supply.
• The main circuit power supply and the control power supply must be two separate input power supplies.
• Power supplies must have double or reinforced insulation that conforms to safety standards.
When choosing molded-case circuit breakers and fuses for input power supplies on the AC side, confirm the
specifications of the input power supplies and refer to this table.
Also, choose molded-case circuit breakers and fuses that meet the following cutoff characteristics.
Cutoff characteristics (25°C): ⋅300% of the rated load input current, five seconds min.
Main
SERVOPACK
Circuit
Model
Power
SGDV-
Supply
24 VDC
1R7E
48 VDC
24 VDC
2R9E
48 VDC
∗1. Values with instantaneous maximum load.
∗2. Values with rated load.
Power Supply
SERVOPACK
Capacity per
Model
SERVOPACK
SGDV-
[W]
11
1R7E
30
2R9E
11
1R7E
30
2R9E
⋅Does not cut off at the inrush current value of the power supply.
Max.
Power Supply
Applicable
Capacity per
Servomotor
SERVOPACK
Capacity
*1
[W]
[W]
11
169
165
30
411
Main
Output
Circuit
Current
Power
[Arms]
Loss
[W]
[W]
169
1.7
3.4
165
2.9
6.9
169
1.7
3.4
411
2.9
6.9
Input Current Capacity
Main Circuit
Control
Circuit
Continuous
Instantaneous
Rated
Max.
[A]
[A]
2.0
8.5
1.0
4.5
3.5
8.5
2.0
10.5
3.1 Main Circuit Wiring
Control
Total
Circuit
Power
Power
Loss [W]
Loss [W]
10.6
14.1
7.2
10.6
14.1
Rated Voltage
Fuse
MCCB
[V]
[V]
100
100
*2
V
400
V
400
[A]
200
V
200
V
V
V
0.3
250
600
240
480
3
3-5

Hide quick links: