Fig.15
`4. Place 4 medium coals on each spar of the
matrix with their corners touching. (see fig. 16 &
17)
Fig.16
Fig.17
5. Place one small coal on each of the 4 medium
coals (see fig.18).
Fig.18
6. Place 4 large coals on the rear of the matrix with
their corners touching. (see fig. 19)
Fig.19
7. Place 2 medium coals each two thirds on top of
the large coals and on third of the small coals,
with their edges touching. Also place one medi-
um coal each side of the matrix. (see fig.20)
Fig.20
I M P O R TA N T: Leave an air space around
each coal to allow easy flow of products of
combustion, too much impingement of flame
on coals will cause sooting.
BEFORE LIGHTING
Purge air from the supply line as follows:
a
Open main shut-off valve. Unscrew inlet pres-
sure test point. Leave inlet test screw open until
gas comes.
b
When gas comes tighten inlet screw immediate-
ly.
WARNING: Do not purge the system near a
naked flame or hot surface.
STOVE OPERATION
WARNING: Do not operate the stove with the
appliance door open, or if the glass panel in
the front door has been broken or removed.
Ensure the door latch is fully locked. Keep the
door spin valve closed at all times when the
stove is in operation.
During the first light up period an odour will rise from
the stove, this is due to the materials in the stove
9