Fault codes
(cont.)
Display
Const.
Weath.-
fault
comp.
code
Fd
X
X
FE
X
X
FF
X
X
System char-
Cause
acteristics
Burner
Fault at the
blocked
burner con-
trol unit
Burner
Strong inter-
blocked or in a
ference
fault state
(EMC) field
nearby, or
faulty main
PCB
Burner
Strong inter-
blocked or in a
ference
fault state
(EMC) field
nearby, or in-
ternal fault
Troubleshooting
Measures
Check the ignition
electrodes and
connecting
cables/leads;
check whether
there are strong
interference
(EMC) fields near
the equipment;
press "E" . If fault
is not removed,
replace control
unit
Start the equip-
ment again. Re-
place the control
unit if the equip-
ment will not re-
start.
Start the equip-
ment again. Re-
place the control
unit if the equip-
ment will not re-
start.
77