Viessmann Vitodens 200 Service Instructions Manual page 75

Type wb2a, 8.8 to 20.0 kw wall mounted gas fired condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Fault codes
(cont.)
Display
Const.
Weath.-
fault
comp.
code
F1
X
X
F2
X
X
F3
X
X
F4
X
X
System char-
Cause
acteristics
Burner in a
Flue gas
fault state
temperature
limiter has
responded.
Burner in a
The tem-
fault state
perature lim-
iter has
responded.
Burner in a
Flame signal
fault state
is already
present at
burner start.
Burner in a
No flame sig-
fault state
nal.
Troubleshooting
Measures
Check the heating
system filling
level. Vent the
system.
Press reset but-
ton "E" after the
flue gas system
has cooled down.
Check the heating
system filling
level. Check the
circulation pump.
Vent the system.
Check the tem-
perature limiter
and connecting
cables.
Press "E".
Check the ionisa-
tion electrode and
lead.
Press "E".
Check the ionisa-
tion electrode and
lead, measure the
ionisation current,
check the gas
pressure, check
the gas combina-
tion valve, igni-
tion, ignition
module, ignition
electrodes and
the condensate
drain.
Press "E".
75