Viessmann Vitodens 200 Service Instructions Manual page 44

Type wb2a, 8.8 to 20.0 kw wall mounted gas fired condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in the delivered condition
53:1
Function connection sK
of the internal exten-
sion: DHW circulation
pump
54:0
Without solar control
unit
DHW
56:0
Set DHW temperature
adjustable from 10 to
60 °C
58:0
Without auxiliary func-
tion for DHW heating
59:0
Cylinder heating:
Starting point -2.5 K
Stopping point +2.5 K
5b:0
DHW cylinder directly
connected to the boiler
60:20
During DHW heating,
the boiler water tem-
perature is max. 20 K
higher than the set
DHW temperature
44
Possible change
53:0
Function connection sK:
Central fault
53:2
Function connection sK:
External heating circuit
pump (heating circuit A1)
53:3
Function connection sK:
External cylinder primary
pump
54:1
With Vitosolic 100 (auto-
matic adjustment on con-
nection)
54:2
With Vitosolic 200 (auto-
matic adjustment on con-
nection)
56:1
Set DHW temperature
adjustable from 10 to
above 60 °C
Note
Maximum value subject
to boiler coding card
Observe the maximum
permissible DHW tem-
perature
58:10
Input of a second set
to
DHW value, adjustable
58:60
from 10 to 60 °C (observe
coding addresses "56"
and "63")
59:1
Starting point adjustable
to
from 1 to 10 K below the
59:10
set value
5b:1
DHW cylinder connected
downstream of the low
loss header
60:5
The difference between
to
the boiler water tempera-
60:25
ture and the set DHW
temperature is adjustable
from 5 to 25 K