Viessmann Vitodens 200 Service Instructions Manual page 69

Type wb2a, 8.8 to 20.0 kw wall mounted gas fired condensing boiler natural gas and lpg version
Hide thumbs Also See for Vitodens 200:
Table of Contents

Advertisement

Fault codes
(cont.)
Display
Const.
Weath.-
fault
comp.
code
28
X
30
X
X
38
X
X
40
X
48
X
50
X
X
58
X
X
System char-
Cause
acteristics
Regulates
System flow
without flow
temperature
temperature
sensor lead
sensor (low
broken
loss header)
Burner
Boiler water
blocked
temperature
sensor
shorted out
Burner
Boiler water
blocked
temperature
sensor lead
broken
Mixer closes.
Heating cir-
cuit with
mixer M2
flow tem-
perature
sensor
shorted out
Mixer closes.
Heating cir-
cuit with
mixer M2
flow tem-
perature
sensor lead
broken
No DHW heat-
Cylinder
ing
temperature
sensor
shorted out
No DHW heat-
Cylinder
ing
temperature
sensor lead
broken
Troubleshooting
Measures
Check the low
loss header sen-
sor (see page 79).
Check the boiler
water tempera-
ture sensor (see
page 79).
Check the boiler
water tempera-
ture sensor (see
page 79).
Check the flow
temperature sen-
sor.
Check the flow
temperature sen-
sor.
Check sensors
(see page 79).
Check sensors
(see page 79).
69