5. Carefully slide the services gateway onto the mounting shelves so that the bottom of the chassis and
the mounting shelves overlap by approximately 2 in.
6. Slide the services gateway onto the mounting shelves until the mounting brackets or front-mounting
flanges contact the rack rails. The shelves ensure that the holes in the mounting brackets and the
front-mounting flanges of the chassis align with the holes in the rack rails.
7. Move the lift away from the rack.
8. To install the services gateway in an open-frame rack, install a mounting screw into each of the open
mounting holes aligned with the rack, starting from the bottom.
9. Visually inspect the alignment of the services gateway. If the services gateway is installed properly in
the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws
on the opposite side and the services gateway should be level.

Reinstall Components

To reinstall the components in the services gateway:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis. For more information about ESD, see the SRX5800 Services
Gateway Hardware Documentation at www.juniper.net/documentation/.
2. Slide each component into the chassis evenly so that it does not become stuck or damaged.
3. Tighten the captive screws for each component.
NOTE:
Make sure that all empty slots are covered with blank panels before you operate the services
gateway.
Proceed to
"Step 4: Connect the Grounding Cable" on page
13.