Displayed Messages - Rinnai RDT-62-RM-W Operating Instructions Manual

Gas clothes dryer
Table of Contents

Advertisement

Displayed Messages

When the safety interlock operates, you will be notified on the
display and by a buzzer, and cool operation will automatically
be performed.
During cool operation, the SOFTEN&COOL lamp lights. Wait
for this lamp to automatically go out.
The blinking display goes out by pressing the "Power" switch after cool operation ends.
Display
For displays marked by *, the buzzer
does not sound.
At power outage
<out>
At power ON again
<blinks>
<blinks>
<blinks>
<blinks>
<blinks>
<blinks>
<blinks>
45
*
Safety interlock at power outage
Temperature detection thermistor
(blocked filter error)
Ignition/light out safety Interlock
Temperature detection thermistor
(discharge temperature thermistor)
Temperature detection thermistor
(clothes temperature thermistor)
Switch circuit safety interlock
Safety Interlock
Gas supply and operation is stopped when a power
outage occurs. Also, the equipment cannot be used
during a power outage.
Gas supply is stopped and cool operation is
automatically started when lint blocks the lint filter
or when the inside of the equipment overheats
abnormally.
Gas supply is stopped and cool operation is
automatically started when lighting of the pilot light
fails during ignition.
Gas supply is stopped and cool operation is
automatically started when flames go out during use.
Gas supply is stopped and cool operation is
automatically started when the inside of the
equipment overheats abnormally.
Gas supply is stopped and cool operation is
automatically started when the inside of the
equipment overheats abnormally.
Gas supply is stopped and cool operation is
automatically started when an abnormality occurs on
the start/pause switch circuit.