Planet FGSW-2022VHP User Manual page 34

12-port 10/100tx 802.3at poe + 4-port 10/100tx 802.3bt poe + 2-port gigabit tp + 2-port sfp ethernet switch with lcd management
Table of Contents

Advertisement

The data pairs are used. Since Ethernet pairs are transformers coupled at each
end, it is possible to apply DC power to the center tap of the isolated transformer
without upsetting the data transfer. In this mode of operation, the pair on pins 3
and 6 and the pair on pins 1 and 2 can be of either polarity.
POWER SOURCING
EQUIPMENT (PSE)
+ / -
TX
+ / -
48V
RX
 When to install PoE
Consider the following scenarios:
z You're planning to install the latest VoIP phone system to minimize cabling
building costs when your company moves into a new office next month.
z The company staff has been clamoring for a wireless access point in the picnic
area behind the building so they can work on their laptops through lunch, but
the cost of electrical power to the outside is not affordable.
z Management asks for IP Surveillance Cameras and business access systems
throughout the facility, but they would rather avoid another electrician's
payment.
34
4
5
SPARE PAIR
1
2
SIGNAL PAIR
3
6
SIGNAL PAIR
7
8
SPARE PAIR
Figure 2: Power Supplied over Data Pins
POWERED DEVICE
(PD)
4
5
1
RX
2
DC / DC
3
Converter
TX
6
7
8

Advertisement

Table of Contents
loading

Table of Contents