Addition To The Memory Card I/F: Cu-200 - Furuno FAR-2107 Series Service Manual

Marine radar/arpa
Hide thumbs Also See for FAR-2107 Series:
Table of Contents

Advertisement

4.8 Addition to the Memory Card I/F: CU-200

When the second CU-200 unit is connected to the network, the IP address of the second
unit should be changed. Up to two units can be connected to the network.
NETWORK
RPU-013
LAN
(Straight cable)
S1
1
INIT
2
IP2
3
IP1
4
IP0
1. . . . Setting
1. Turn the power off.
2. Set IP0 and INIT of DIP switch (S1) to ON.
3. Turn the power on and wait until CR2 starts to blink.
4. When CR2 starts to blink, turn the power off and return INIT of S1 to OFF.
5. IP address was changed from 172.031.014.100 to 172.031.014.101.
NET-100 board
LAN
HUB
LAN
LAN
(Straight cable)
LAN (Cross cable)
Fig. 4.8.1 Connection of CU-200
No.1 CU-200
OFF
OFF
OFF
OFF
S1 (DIP SW)
#1: INIT #3: IP1 #2: P2 #4: IP0
4-48
4.8 Add to the Memory Card I/F: CU-200
Note:
No.2
When connecting RPU-013 and CU-200
CU-200
directly, Cross cables are used. When the
HUB-100 is used for the connection,
No.1
CU-200
either straight cable or cross cable can be
used. The HUB-100 automatically detects
all the ports and cable types.
Table 4.8.1 Setting of IP address of CU-200
No.2 CU-200
OFF
OFF
OFF
ON
CARD CPU board
(03P9333)
Fig. 4.8.2 Location of S1 on CU-200
Default
OFF
OFF
OFF
OFF
CR2: CPU (U12) RUN
Blinks for every second.