4.4.5 RADAR NO.

INITIALIZE -> 4: INSTALLATION -> 4
This is the setting of the own radar (ANT) number. When the ANT number is specified,
the IP address is automatically assigned.
After you change the radar number, wait until a message "Completed!! Power on
restart" is displayed. And then, restart the power.
You can check the radar IP address set in "MENU->0 -> 7:NETWORK".
See p.4-34 for setting the IP address, subnet mask and default gateway, if necessaly.
Important:
To make the unit work as a radar, set the radar number to 1 to 4.
RADAR No. 1 to 4: With ANT unit
RADAR No. 1: 172.031.003.006
RADAR No. 2: 172.031.003.007
RADAR No. 3: 172.031.003.008
RADAR No. 4: 172.031.003.009
To make the unit work only as a monitor of the inter-switch, set the radar number 5 to 8.
RADAR No. 5 to 8: Without ANT unit
RADAR No. 5: 172.031.003.010
RADAR No. 6: 172.031.003.011
RADAR No. 7: 172.031.003.012
RADAR No. 8: 172.031.003.013
Note!!
When changing the IP address (RADAR NO.) of the radar connected with the
LAN, be sure to restart the power for other radars, HUB-100 and CU-200
connected to the LAN.