Change Of Transmission Hv Setting: Hv-9017 - Furuno FAR-2107 Series Service Manual

Marine radar/arpa
Hide thumbs Also See for FAR-2107 Series:
Table of Contents

Advertisement

4.14 Change of Transmission HV setting: HV-9017

The setting of jumpers JP1 and JP2 changes the transmission high voltage for TR units of 12
kW and 25 kW to 60 kW. TX output can be checked on "SER.NO." of the nameplate of
RPU-013. The serial number differs according to the setting of the HV-9017 board.
- SER NO. 4317-xxxx -> 12 kW-type: HV-9017 A (310 to 350 V)
- SER NO. 4318-xxxx -> 25 kW or more: HV-9017 B (520 to 580 V)
Note:
The nameplate of a unit for overseas model includes the description of TX output. In Japanese
model, TX output is known from the description of "MODEL" and "APPROVED TYPE" on the
nameplate.
Nameplat of oversea model
PROCESSOR UNIT
25kW. 30kW. 50kW. 60kW
Nameplat of Japanese model
RPU-013
4318-0032
Fig. 4.14.1 Example of RPU-013 Nameplate
HV-9017 board
Fig. 4.14.2 HV-9017 Board and HV Check points
4.14 Change of Transmission HV setting: HV-9017
MODEL FAR-2127-20AF
RCS2FD9-25KP0N-4
J651: HV
4-69
R03019
2003-12-19
2004-6
4318-0524
MU-201CR
XN20AF-RSB-096

Advertisement

Table of Contents
loading

Table of Contents