5022-xxx
Toner level sensor removal
Black and Magenta
1.
Remove HVPS. See
2.
Depress locking tabs (A) on sensor; remove sensor.
Cyan and Yellow
3.
Remove transfer contact assembly. See
remove springs from contact assembly as stated in last step of procedure.
4.
Depress locking tabs (A) on sensor; remove sensor.
4-58
Service Manual
"High volt power supply (HVPS) removal" on page
"Transfer contact assembly removal" on page
4-55.
4-57. Do not