Cam Track TO - Part II
4.2 TO Cam Track basics
One cam track with the following data is given.
● Three position-based cams (30-60; 110-120; 170-190)
● Track length: 100
● Axis reference position: 0
● All other user-default variables are the default setting unless another setting is mentioned
0
Single output cams of the cam track are mapped onto the track
length and the position is recalculated. A new output cam track
results.
0
Display of given cam track with modified activation mode and axis reference position
● Activation mode: Cyclic
● Mode: Cyclic
● Axis reference position: 20
● Position at which _disableCamTrack occurs: 150
98
explicitly.
Mapping
50
50
Mapping
100
150
100
150
200
200