To configure a measuring input on a TM15/TM17 High Feature
1. In the project navigator, below the input/output component (TM15/TM17) that you want to
2. For the selected I/O channel, select measuring input as the function.
3. Insert a new measuring input or use an existing one.
4. Assign parameters to the measuring input TO.
5. Double-click Configuration below the measuring input in the project navigator. The
6. Activate the option Standard (global measuring input). Assignment of an output to a
7. Click OK to close the window and select Project > Save.
To determine the logical hardware address for a TM15/TM17 High Feature (only if symbolic assignment
is not activated)
1. For TM15/TM17 modules, the hardware addresses result from the configured address
2. In the project navigator, below the input/output component (TM15/TM17) that you want to
3. Find the input that you want to use (Measuring input must be selected under Function) and
4. In the project navigator, below the SIMOTION device or the SINAMICS drive unit, select
Output Cams and Measuring Inputs
Function Manual, 04/2014
use, double-click the entry Inputs/outputs. The Bidirectional Digital Inputs/Outputs window
is displayed.
Note
If you do not use symbolic assignment (see Section Symbolic Assignment (as of V4.2) in
the SIMOTION Runtime Basic Functions manual), you must note the offset (e.g. 3.1).
Configuration window appears in the working area.
measuring input is supported as of V4.2 by symbolic assignment (see Section Symbolic
Assignment (as of V4.2) in the SIMOTION Runtime Basic Functions Manual) or by entering
the hardware address. In order to assign a physical output, the HW address and bit number
must be entered in the Output field.
range, and the bit numbers from the offset.
use, double-click the entry Inputs/outputs. The Bidirectional Digital Inputs/Outputs window
is displayed.
note the offset (e.g. 3.0).
– For SIMOTION D:
SINAMICS_Integrated > Communication > Telegram configuration
– For the SINAMICS S120 drive unit:
Communication > Telegram configuration
5.3 Configuring the Measuring Input technology object
Measuring Input TO - Part III