Download Print this page

Siemens SIMOTION Function Manual page 17

Motion control, output cams and measuring inputs
Hide thumbs Also See for SIMOTION:

Advertisement

Features
Different types of output cam
on one output
Output cam definition
Hysteresis
Effective direction
Derivative-action times
Deactivation time for time-
based cam
Activation/deactivation types
Types of output
Output cam status
Output cam enable
Performance
MCC command available
Output Cams and Measuring Inputs
Function Manual, 04/2014
Output Cam TO
● Via AND/OR
● Related to axis
● Via system variables
● Available
● Available
● Separate for power ON/power OFF
● As of Version V3.2
● Active immediately
● Cyclic
● System variable
● Via_enableOutputCam
● Depends on number of single output
cams
● Available
Output Cam TO - Part I
3.1 Overview of Output Cam TO
Cam Track TO
● Not available
● Related to cam track (cam track can be
mapped as required on axis)
● Via system-variables array
● Available
● Not available
● Separate for power ON/power OFF
● As of Version V3.2
● Start and stop mode parameterizable
● Cyclic
● Once
● Status of single output cams over one
array of byte
● via_enableCamTrack
● Validity of single output cams configurable
via system variables
● When 5 or more output cams are used in
one output cam track instead of 5 single
output cams, the output cam track
performs better. This performance
advantage amounts to at least a factor of
2 for 32 single output cams.
● Available (V4.0 and higher)
17

Hide quick links:

Advertisement

loading